DS3000/3500 |
DS4000 |
DS3550/4500 | ||
Input Voltage |
All rated load conditions |
| ||
Normal Line |
120/240 [V] AC |
| ||
Input Frequency |
|
| ||
Overvoltage Protection |
+5[V] DC |
| ||
-5[V] DC |
| |||
+12[V] DC |
| |||
-12[V] DC |
| |||
Output Power |
- |
210[W] |
288[W] |
245[W] |
AC Leakage (*1) Current to GND |
Input 250[V] AC rms 50HZ |
| ||
Ripple and Noise (*2) Peak-to-peak |
All outputs within line and load specifications (500kHz Bandwidth) |
| ||
| ||||
| ||||
| ||||
Load Current |
+5[V] DC |
10[A] min, 24[A] max |
10[A] min, 40[A] max |
10[A] min, 30[A] max |
-5[V] DC |
0 to 0.5[A] |
0 to 0.05[A] |
0 to 0.5[A] | |
+12[V] DC |
|
| ||
-12[V] DC |
| |||
120[V] AC |
0 to 2[A] rms |
| ||
240[V] AC |
0 to 1[A] rms |
| ||
AC Input Current |
90 to 132[V] rms |
7.4[A] rms (*3) |
11[A] rms (*3) |
9.5[A] rms (*3) |
187 to 264[V] rms |
3.7[A] rms (*3) |
5.5[A] rms (*3) |
5.0[A] rms (*3) | |
Hold-Up Time |
After the POWER GOOD signal goes low (false), the supply voltage hold within tolerance for 500 microseconds (2milliseconds for DS3550,4000,4500) | |||
(*1) Not includeing monitor leakage current. (*2) Because radio frequencies are involved when measuring ripple and noise, spurious pickup is a possibility. To minimize this risk, measure noise and ripple using a 1:1 probe with the shortest possible lead lengths outside the grounded shield. (*3) Includes monitor outlet load. |
Original document: "Domain Personal Workstations and Servers Technical Reference (APN: 008778-A01)"