DS3000/3500/4000/3550/4500

Power Supply Operation Parameters

Parameters

Conditions

Specifications

DS3000/3500

DS4000

DS3550/4500

Input Voltage

All rated load conditions

90 to 132 [V] AC rms

187 to 264 [V} AC rms

Normal Line

120/240 [V] AC

Switch Selectable

Input Frequency

-

50HZ(+-3Hz)

60HZ(+-3Hz)

Overvoltage Protection

+5[V] DC

6.25[V] (+-0.75[V])

-5[V] DC

-6.25[V] (+-0.75[V])

+12[V] DC

14[V](+-1.0[V])

-12[V] DC

-14[V](+-1.0[V])

Output Power

-

210[W]

288[W]

245[W]

AC Leakage (*1) Current to GND

Input 250[V] AC rms 50HZ

0.75[mA] max

Ripple and Noise (*2) Peak-to-peak

All outputs within line and load specifications (500kHz Bandwidth)

+5 (2%)

-5 (2.5%)

+12 (1%)

-12 (2.5%)

Load Current

+5[V] DC

10[A] min, 24[A] max

10[A] min, 40[A] max

10[A] min, 30[A] max

-5[V] DC

0 to 0.5[A]

0 to 0.05[A]

0 to 0.5[A]

+12[V] DC

1[A] min, 6[A] max

7.4[A] peak for 20 [Sec]

1[A] min, 6.5[A] max

7.4[A] peak for 20 [Sec]

-12[V] DC

0 to 0.5[A]

120[V] AC

0 to 2[A] rms

0 to 3[A] rms

240[V] AC

0 to 1[A] rms

0 to 1.5[A] rms

AC Input Current

90 to 132[V] rms

7.4[A] rms (*3)

11[A] rms (*3)

9.5[A] rms (*3)

187 to 264[V] rms

3.7[A] rms (*3)

5.5[A] rms (*3)

5.0[A] rms (*3)

Hold-Up Time

After the POWER GOOD signal goes low (false), the supply voltage hold within tolerance for 500 microseconds (2milliseconds for DS3550,4000,4500)

(*1) Not includeing monitor leakage current.

(*2) Because radio frequencies are involved when measuring ripple and noise, spurious pickup is a possibility. To minimize this risk, measure noise and ripple using a 1:1 probe with the shortest possible lead lengths outside the grounded shield.

(*3) Includes monitor outlet load.

Original document: "Domain Personal Workstations and Servers Technical Reference (APN: 008778-A01)"